| Model | VTS-1013-N | |
| Equipment parameters | Overall dimensions | 6567*1420*1520mm |
| Plate size | 70*50mm-300*350mm | |
| Number of heating zones | 9 | |
| Length of heating zones | 3420 | |
| Number of cooling zones | Upper 3 | |
| Cooling method | Water cooling – external chiller | |
| Process edge | Standard 5mm, customizable | |
| Plate height | 25mm on the board, 15mm below the board | |
| Transmission parameters | Transmission mode | Chain |
| Transmission control mode | Heating zone and vacuum section servo + cooling zone frequency conversion | |
| Transmission speed | 200-2400mm/min | |
| Transmission height | 900±20 | |
| Transmission direction | L-R or R-L | |
| Vacuum parameters | Number of vacuum zones | 1 |
| Ultimate vacuum pressure | 10-100pa | |
| Vacuum pumping speed | 60 cubic meters/hour, adjustable | |
| Minimum cycle for vacuum welding | 25Sec (action time can be set) | |
| Release method | Nitrogen quick release | |
| Vacuum chamber operation method | Servo control | |
| Vacuum zone track | Servo width and narrow adjustment | |
| Flux recovery system | Independent vacuum zone recovery device | |
| Control parameters | Control mode | PC+Siemens PLC |
| Temperature control mode | PID+SSR | |
| Temperature control range | Normal temperature -350℃ | |
| Temperature control accuracy | ±1℃ | |
| Heat-up time | ≤30min | |
| Heat conduction mode | Hot air independent temperature zone circulation, variable frequency speed regulation | |
| Startup/normal operation power | Startup: 45KW, normal operation 15KW | |
| Power failure protection | UPS endurance operation | |
| MES data | Secondary development possible | |
| Nitrogen device | Nitrogen filling method | The whole area is filled with nitrogen, and the vacuum area is sampled. |
| Nitrogen flow rate | 100-1000ppm @35 cubic meters/hour, nitrogen purity 99.999% | |